Mendota DXV-60 Betriebsanleitung Seite 50

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 49
49
NATURAL TO LP GAS CONVERSION INSTRUCTIONS
Kit # HA-30-00507 Mendota Model DXV35 DT3
This conversion kit shall be installed by a qualified
service agency in accordance with the manufactur-
er’s instructions and all applicable codes and re-
quirements of the authority having jurisdiction. If the
information in these instructions is not followed ex-
actly, a fire, explosion or production of carbon mo-
noxide may result causing property damage,
personal injury or loss of life. The qualified service
agency is responsible for the proper installation of
this kit. The installation is not proper and complete
until the operation of the converted appliance is
checked as specified in the owner instructions sup-
plied with the kit.
Caution: The electrical supply to the fireplace must
be turned off prior to performing the conversion. The
gas supply must be shut off prior to disconnecting
the electrical power.
ORIFICE SIZES REQUIREMENT:
A Natural Gas to LPG conversion kit #HA-30-00507
is Optional and must be purchased separately.
LP Conversion Kit # HA-30-00507 contains the fol-
lowing parts: One Motorized LP Pressure Regulator #907.012, One LP Pilot Orifice Thimble #977.168, and two Cap Ori-
fices #65-14-00364(drill #3/64”) and an L-shaped Torx wrench.
RECOMMENDED PROCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG
This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recommend-
ed that you convert this fireplace and its Pressure Regulator, Pilot Orifice Thimble and Burner Orifices prior to placing this
fireplace in its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Using a ¼” Hex Driver, remove 2 screws that secure the Rear and Front burners to the Burner Airbox.
2. Lift Up and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼” minimum. Set burner aside.
4. Slide Rear Burner to the right about 2” and lift up and remove from Firebox.
BURNERS MOUNTING
SCREWS
FRONT BURNER
REAR BURNER
LP Pilot Orifice
[#977.168]
Burner Orifices
#65-14-00364[3/64" DRILL]
Motorized
LP Pressure
Regulator
[10.0-5.5"WC]
# 907.012
364
364
Seitenansicht 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 63 64