Mendota DXV-60 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Kamine Mendota DXV-60 herunter. Mendota DXV-60 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
MENDOTA GAS DIRECT VENT FIREPLACE
with
Premium Texture Fiber Logs Combustion System
Model DXV-35 DT3 - LX
INSTALLATION & OPERATING INSTRUCTIONS
NO. LX-1111
WARNING
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
CAUTION: Keep gasoline and other liquids having flam-
mable vapors away.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre
les instructions dans la présente notice risque de dé-
clencher un incendie ou une explosion entraînant des
dommages, des blessures ou la mort.
ATTENTION. Garder l’essence ou autres liquides produi-
sant des vapeurs inflammables loin del’appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur; ne pas vous servir
des téléphones se trouvant dans le bâtiment.
Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
Si vous ne pouvez rejoindre le fournisseur, appelez
le service des incendies.
N’utilisez pas cet appareil s’il a été plongé dans l’eau,
même partiellement. Faites inspecter l’appareil par un
technicien qualifiéet remplacez toute partie du système
de contrôle et toute commande qui ont été plongés dans
l’eau.
AVERTISSEMENT : Une installation, un réglage, une modifi-
cation, une réparation ou un entretien mal effectué peut cau-
ser des dommages matériels ou des blessures. Voir la notice
de l'utilisateur quiaccompgne l’appareil. Pour de l’aide oueds
renseignements supplémentaires, consultez un installateur,
un technicien agréé ou le fournisseur de gaz.
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional informa-
tion consult a qualified installer, service agency or the gas
supplier.
Seitenansicht 0
1 2 3 4 5 6 ... 63 64

Inhaltsverzeichnis

Seite 1 - Model DXV-35 DT3 - LX

MENDOTA GAS DIRECT VENT FIREPLACE with Premium Texture Fiber Logs Combustion System Model DXV-35 DT3 - LX INSTALLATION & OPERATING INSTRUCTIONS

Seite 2

9 GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced, highly effic

Seite 3

10 VENT OPTIONS DISCUSSION This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY and ICC brands of c

Seite 4

11 GAS SUPPLY REQUIREMENTS Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fi

Seite 5

12 GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Problems such as changes in flame

Seite 6

13 EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 2: Exterior Vent Locations ∨ - Vent Terminal ALL MEASUREMENTS GIVEN ARE FROM THE CENTER LINE OF

Seite 7

14 GENERAL FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using Amerivent, Duravent, Selkirk Metalbestos, Security Chimney or ICC Br

Seite 8

15 GENERAL INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas

Seite 9 - CAUTION

16 outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are allowed

Seite 10

17 TOP FLUE VENTING COMPONENTS ITEM DESCRIPTION 1 12" VENT STACK 1 24" VENT STACK 1 36" VENT STACK 1 48" VENT STACK 2 90ºGALVA

Seite 11 - Limitation 2

18 FLUE VENTING ALLOWANCE CHART NOTE: FOR LP GAS & HIGH ALTITUDE, SEE PG. 19 NOTE: FOR LPG AND HIGH ALTITUDEAPPLICATIONS, SEE PAGE 19. NOTEFig

Seite 12

In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter; • A CO

Seite 13

19 L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in plac

Seite 14 - ∧ - Air Supply Inlet

20 MINIMUM RISE THROUGH-THE-WALL VENTING: The minimum vertical rise for vent installation through the wall is 16 1/4" from the top of the firep

Seite 15 - WARNING

21 VENTING COMPONENTS LIST NOTE: ALL PART NUMBERS LISTED ABOVE APPLY TO SIMPSON DURAVENT COMPONENTS ONLY. MENDOTA # DESCRIPTION45-01-00186 7&quo

Seite 16

22 ELEVATED VERTICAL RISE THROUGH-THE-WALL VENTING The required MINIMUM vertical rise is 48 in. when used with a maximum horizontal run of 12 ft. F

Seite 17 - 85-03-00458

23 VERTICAL THROUGH-THE-ROOF VENTING The maximum vertical run of vent pipe is 55 ft. from the top of the fireplace. The fireplace will support a ru

Seite 18

24 2.) PULL3.) ROTATE4.) RELEASE1.) INSERTDOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken.

Seite 19 - APPLICATIONS, SEE PAGE 19

25 GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT TO REPLACE DAMAGED GLASS 1. Using an 1/8” drill bit, drill through 3 rivets on each side of glass

Seite 20 - 85-03-00531

26 DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET. CAUTION: LOGS

Seite 21

PLACELOG#1(REARLOG) ONREARSHELFBEHINDREARBURNER.PUSHLOGINTORECESS IN BACK BRICK PANELLOG# 1RECESSINBACKBRICKPANEL.THERECESSSHAPEM

Seite 22

LOG#2(MIDEMBERBED)SITSBETWEENREARANDFRONTBURNER,FLATDOWNONTHESURFAC EOFTHEBURNERAIRBOX.ADJUSTPOSITIONOFFRONTANDREARBURNERSI

Seite 23

2 DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION EXTERNAL DIMENSIONS: 35-7/8” Wide X 31-1/2” High X 15-1/2” Deep MINIMUM FRAMING DIMENSIONS: 37-1

Seite 24

PLACELOG#3(LEFTLOG)ONTOPOFTHE RECTANGLEAIRSHUTTERBOXONTHELEFTSIDE.LOG#3HASARECTANGULARNOTCHONITSBOTTOMSIDETHATALLOWS THE L

Seite 25 - DETAIL A

LOG#4(RIGHTLOG)HASAHOLEFORTHEPINONLOG#2.INSERTPININLOG#2INTOHOLEINLOG#4.LOG#4.SOMEROTATIONALFLEXIBILITYISALLOWEDTOLOG#4

Seite 26 - FLAT FORM

LOG#5(LEFTTOPLOG)SITSONTHELEFTSHOULDEROFLOG#1ANDITSTWOBRANCHESSITONTOPOFLOG#2ANDLOG#3.LOG#5HASAHOLETHATALIGNSWITHTHE

Seite 27

LOG#6(RIGHTTOPLOG)SITSONTOPOFLOG#1USINGTHEPINTHATISONTHERIGHTSIDEOFLOG#1.LOG#6HASAHOLEINITSBACK‐SIDETOMATEWITHTHISP

Seite 28

LOG#7LOG#7RESTONTOPOFTHEFRONTBURNER’SREARVISIBLEEDGEANDONTOPOFLOG#4. THISLOGISDESIGNEDTOHIDETHEPILOTLIGHT.PLACETHISLOGS

Seite 29

PLACELOG#8(LEFTFRONTTWIG)INTHEPOSTIONSHOWNHERE.LOG#8SITSONTOPOFLOG#2ANDRESTSAGAINSTTHEGRATEBAR(2NDFROMLEFT).LOG#8ATTEMPTT

Seite 30

LOG#9LOG# 9LOG#9LOG#9(RIGHTFRONTCHUNK)ISTOBEPLACEDATASEVEREANGLEAGAINSTTHEHORIZONTALGRATEBARANDFLOATINGOVERTHEFRONTBURNERPOR

Seite 31 - ONTOPOFLOG#2,HERE

COMPLETEDLOGSETASSEMBLY36

Seite 32

37 The following Check Off Lists mustINSTALLATION CHECK OFF LIST be completed prior to final operation of the Fireplace, or manufac-turer's wa

Seite 33

38 BEFORE YOU BEGIN Read this entire manual before you use your new fireplace. Failure to follow the instructions may result in property dam-age, b

Seite 34

3 TABLE OF CONTENTS FOR YOUR SAFETY READ BEFORE LIGHTING ...

Seite 35

39 Remote Control Transmitter Functions NOTE: The Wall Receiver will “beep” once every time a Remote Transmitter Key is pressed, signaling that the

Seite 36

40 REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE1. Press the ON/OFF button. The transmitter display will show all active i

Seite 37 - COMPLETEDLOGSETASSEMBLY

41 MANUAL BYPASS OF THE REMOTE SYSTEM If the remote transmitter is misplaced or lost, the appliance can be turned on manually by sliding the three

Seite 38

42 “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have

Seite 39 - ATTENTION!

43 Backup Batteries The life span of the backup batteries depends on the quality of the batteries used and how long the batteries have been installe

Seite 40 - ON SMART

44 BLOWER OPERATION AND WIRING WARNINGDual blowers are provided as standard equipment with this DXV35 DT3 Fireplace. The dual blowers have an air

Seite 41 - MODE KEY

45 TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating (soot) forms on viewing glass. A.

Seite 42

46 CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURE Mendota Fireplaces comply with UL Standards for maximum surface t

Seite 43 - REMOTE TRANSMITTER

47 MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approved serv

Seite 44

48 WIRING SCHEMATICS Note: The DXV35-DT3-LX ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power out

Seite 45

4 INITIALIZING THE REMOTE CONTROL SYSTEM ...

Seite 46

49 NATURAL TO LP GAS CONVERSION INSTRUCTIONS Kit # HA-30-00507 Mendota Model DXV35 DT3 This conversion kit shall be installed by a qualified service

Seite 47

50 Use an Alan WrenchTo loosen and removeNG Pilot Orifice. InstallLP Pilot Orifice, TightenDown.Pull Pilot Hood UPand lift UP off the base.WIRE CLIP

Seite 48

51 10. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air shutter open to ¼” mi

Seite 49

52 INSTALLING THE LP PRESSURE REGULATOR WARNING: READ AND UNDERSTAND ALL INSTRUCTIONS PACKAGED WITH LP PRESSURE REGULATOR BODY BEFORE YOU ATTEMPT T

Seite 50 - REAR BURNER

53 INLET TAP OUTLET TAP LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only ac

Seite 51 - DETAIL C

54 WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! CHECKING FOR NORMAL BURNER (S) I

Seite 52 - -1/4" MINIMUM

55 REPLACEMENT PARTS MENDOTA GAS DXV-35 DT3 FIREPLACE PART NO DESCRIPTION PART NO DESCRIPTION 65-02-00103 TADPOLE GLASS GASKET (106”) 05-04

Seite 53

56 MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION The following Designer Fronts are available for the DXV-35 Fireplace: 1. Andover, Bentley Arc

Seite 54 - 1" MIN

57 HEARTH PAD SURFACE MUST BE FLUSH WITH FIREPLACE BOTTOMIF INSTALLING THE WELLINGTON!!HEARTH PADSURFACEInformation specific to the installation of

Seite 55

58 RATING LABEL REPRESENTATION DXV35 DT3

Seite 56

5 SPECIFICATIONS MODEL DXV-35 DT3 INPUT RATES (Btu/Hr) High Fire - Adjustable to - Low FireNAT. GAS 33,000 10,000 LP GAS

Seite 57 - FIREPLACE’S FACEPLATE

59 THIS PAGE LEFT BLANK INTENTIONALLY

Seite 58 - Figure 10

60 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form ver

Seite 59 - DXV35 DT3

61 TAPE SHUT ------------------------------------------------------------------------------------------------------------------

Seite 60

62 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA DXV-35-DT3-LX DIRECT VENT FIREPLACE Mendota Division of Johnson Gas Applian

Seite 61

Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division

Seite 62

6 Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common

Seite 63

7 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc-tions

Seite 64

8 CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficient Fire

Kommentare zu diesen Handbüchern

Keine Kommentare